Electric Mismatch in Silicon-Cell PV is Not Intuitive

Posted on Fri 18 October 2019 in Solar

Uniform Versus Non-Uniform Shade

The counter-intuitive effect of shade on photovoltaic (PV) solar energy panels surprises most people.

Shade across a relatively small portion of the panel can cause a disproportionately large power loss.

For example, shade across just the bottom row of cells, only 6 cells out of 60, merely 10% of the PV panel, will cause 90% power loss! Why does this happen? Did you think it would cause only 10% power loss? Why isn't power loss linear with shade?

OK, to be fair, if the entire array is uniformly shaded or merely illuminated with a less intense light, then the decrease in power would be proportional to the decrease in light intensity. For example if a giant rain cloud passed over the sun, or the sun slowly sank behind a mountain, so that the same light was cast everywhere, but just lower intensity, say 50%, then the power would be 50% lower as well.

So just to be completely clear, in this post we are not going to talk about the effects of changes in light intensity that are totally uniform everywhere, but instead we're going to focus on what happens when there are non-uniform differences in light intensity across the PV system. Here's an example of a PV system with non-uniform shade.

non uniform shade on a roof

PV Primer

In PV lingo, a panel is called a module which, in most silicon PV modules, is made up of smaller solar cells connected in series. Modules are most often connected in series to form strings of modules. Strings are connected in parallel to an inverter which converts DC from the panels to AC which is sent to the grid.

Here's a typical PV system at the National Institute of Standards and Technology (NIST) in Gaithersburg, MD, which has a single 260-kW inverter connected to 96 strings, each with 12 Sharp NU-U235F2 235-W modules. The first four rows are 5 modules deep, but the last row is only 4 modules deep. The modules are all in landscape and have straight stringing:

NIST Google NIST ground mount racks

Here's a simulation from SolarFarmer showing the shadows cast by the eastern trees.

NIST Google NIST Google

PV Cells and Reverse Bias Breakdown

The cells in a PV module can be considered roughly as a current source in parallel with a diode and some resistive elements. Diodes are semiconductors. In other words, they only conduct current in one direction, called the forward bias. When a negative voltage, or a reverse bias, is applied to the cell, the semiconductor won't conduct a current. However, if enough reverse bias is applied, all semiconductors will eventually breakdown, and carry a current. This phenomema is called reverse bias breakdown, and the breakdown voltage varies between cell technology. A typical front contact p-type silicon solar cell may breakdown at around -20 volts, while a back-contact n-type silicon solar cell may breakdown at -5 volts. There are many factors, beyond the scope of this primer, that affect reverse bias breakdown, such as purity of the substrate as well as type and concentration of dopant. The most important thing to understand about reverse bias breakdown is this:

When a cell is in reverse breakdown, it can carry nearly any current, but because the voltage is negative, then the cell will dissipate energy and will get hot as it exchanges heat with the environment around it.

The Single Diode Model

The electric circuit analog used to describe a solar cell is called the single diode model. Here's a schematic:

Single Diode Model

Image credit: Sandia PV Performance Modeling Collaborative

The solar cell current-voltage relation, or IV curve, shown below demonstrates the forward and reverse bias characteristics of a solar cell. The single diode model matches this response close enough to be used for predictions.

3-quadrant IV curve

Image credit: PV Education, UNSW, ASU, et al.

PV Modules and Bypass Diodes

PV modules are usually designed with bypass diodes to avoid energy loss and hot spots due to cells in reverse bias breakdown by allowing current to bypass the cells in reverse bias breakdown. The figure below shows a 72-cell module with 3 bypass diodes, each in parallel with a 24-cell submodule (aka: substring).

Circuit diagram of the solar module with 72 cells

Credit: Analysis of Power Loss for Crystalline Silicon Solar Module during the Course of Encapsulation by Hong Yang et al., April 2015, International Journal of Photoenergy 2015:1-5 DOI: 10.1155/2015/251615

When the voltage in the submodule exceeds a small trigger voltage in the bypass diode, due to a cell or cells in reverse bias breakdown, then current will flow through the bypass diode, bypassing the entire submodule. For example, if one cell in the submodule is in reverse bias breakdown at -20 volts, and the other 23 cells are all normal at 0.6 volts, then the total voltage of the submodule is -6.2 volts.

$$\begin{align}V_{sub} &= -20[V] + 23\left(0.6[V]\right) \\ &= -20[V] + 13.8[V] = -6.2[V]\end{align}$$

So if the trigger voltage of the bypass diode is -0.5 volts, then the current will pass through the bypass diode. If the module current is 6 amps, then the bypass diode dissipates only 3 watts and avoids losing 36 watts from the bad submodule. What's more important than saving energy though, is that the bypass diode is also a safety device, because the single cell in reverse bias breakdown would have dissipated 120 watts, which could potentially cause a fire, and most likely would cause permanent damage to the cell and the module encapsulant or backsheet.

Electric Circuit Theory

So why does non-uniform shade cause this non-linear effect? If we consider the PV system as an electric circuit, then it must obey the following two laws:

Ohms Law

According to Ohm's law, because the cells and modules in a PV system are all in series, then they must all carry the same current, \(I\), the total voltage of each module, \(V_{mod}\), is the sum of the cell voltages in that module, and the total string voltage, \(V_{str}\), is the sum of the module voltages in the string. In the equation below, \(Z\) represents the impedance of each cell in a module or each module in a string.

$$V = \sum V = I \sum Z$$

The actual relation in a cell is really a bit more complicated than \(V=IZ\), but hopefully this will do to explain electrical mismatch for now. The relation between the flux of charge and solar cell voltage is described by the Poisson Energy Transport Equation but in practice the single diode model circuit discussed above, is a useful analog. For more detail on the single diode model, see this post on examples of implicit vs. explicit solutions for PV systems.

Kirchhoff's Law

Kirchhoff's law requires the voltage across all of the parallel strings to be the same as the voltage across the inverter, and the total current at the inverter nodes to be the sum of the currents from all parallel strings connected to it.

$$I = \sum I = V\sum{\frac{1}{Z}}$$

Electrical Mismatch

The combined effect of enforcing Ohm's and Kirchhoff's laws on a PV system that is partially shaded can cause what's called electrical mismatch. In other words, the shaded cells can't match the current being carried by the rest of the module, or the string with shaded modules can't carry the same voltage as the PV system, and therefore the entire system has to find a new operating condition to satisfy Ohm's and Kirchhoff's laws.

A Rule of Thumb

The counter intuitive behavior of a PV array with partial shade can be understood by remembering the following rule of thumb:

A submodule will perform as well as its most shaded cell.

Imagine a submodule has the bottom cells completely shaded, so they are only getting diffuse light, say 10% of the total plane of array irradiance that's incident on the other cells in the module. The rest of the PV array is operating normally, so the current and voltage of each string might be 7.8 amps and 360 volts, assuming the NIST site shown in the PV Primer above. So, as described in the section on PV Cells and Reverse Bias Breakdown, the two shaded cells can only carry this current in reverse bias breakdown, which would trigger the bypass diode to activate, and cause the string to lose one-third of a module's voltage. However, the strings all have to have the same voltage, and the maximum power point of the system is not going to be at lower voltage, so the bad submodule can't activate it's bypass diode, and the string will have to operate at a lower current - the same current as the bad cell.

PVMismatch

We can analyze this using PVMismatch Python package by SunPower.

TL;DR: A PV system with just 10% of cells shaded in only 1 string, loses nearly all of the power in that string.

Script

The following scrpt uses PVMismatch to model a PV system at STC with 10 strings of 10 SunPower SPR-315E-WHT 96-cell modules per string. Then analyzes the same system, but with the bottom row of cells shaded 80%, ie: only diffuse irradiance:

"""
analyze and plot a 10x10 system with bottom cells of one row shaded
"""

# import the pvmismatch library
from pvmismatch import *

# import the matplotlib plotting library
from matplotlib import pyplot as plt

# make a 10x10 system of SPR-E20-315 96-cell panels at stc
pvsys = pvsystem.PVsystem()

# plot the system
pvsys.plotSys()
plt.tight_layout()

# shade the bottom cell of all modules in the 1st string by 80%
pvsys.setSuns(
    {0: {m: {
        'cells': (11, 12, 35, 36, 59, 60, 83, 84),
        'Ee': (0.2,) * 8} for m in range(10)}})

# plot the btm row shaded system
pvsys.plotSys()
plt.tight_layout()

# btm row shaded system max power
pvsys.Pmp
# 29607.549997102204

# make a new stc system for comparison
pvsys_stc = pvsystem.PVsystem()

# stc system max power
pvsys_stc.Pmp
# 32119.317380452303

# calculate loss
(pvsys_stc.Pmp - pvsys.Pmp) / pvsys_stc.Pmp
# 0.07820114461332704

# btm row shaded string max power
pvsys.pvstrs[0].Pstring.max()
# 720.6607971888608

# stc string max power
pvsys_stc.pvstrs[0].Pstring.max()
# 3212.7324983909575

# calculate loss
(pvsys_stc.pvstrs[0].Pstring.max() - pvsys.pvstrs[0].Pstring.max()) / pvsys_stc.pvstrs[0].Pstring.max()
# 0.7756860250426105

# plot stc string
pvsys_stc.pvstrs[0].plotStr()
f = plt.gcf()
f.axes[0].set_ylim([0, 8])
plt.tight_layout()

# plot btm row shaded string
pvsys.pvstrs[0].plotStr()
f = plt.gcf()
f.axes[0].set_ylim([0, 8])
f.axes[1].set_ylim([-100, 1000])
plt.tight_layout()

PV system at STC

The maximum power at STC is 32,119 [W].

PV system with bottom row shaded

The maximum power with bottom row shaded) is 29,607 [W]. The calculated the relative loss, (pvsys_stc – pvys_btm_row) / pvsys_stc, is 7.8%.

PV string at STC

The string power at STC is 3213 [W].

PV string with bottom row shaded

The string power with the bottom row shaded is 721 [W], and the calculated relative loss, (pvstr_stc – pvstr_btm_row) / pvstr_stc, is 78%.

(Sorry the resolution is a bit poor around the knee, this was a quick simulation using only 100 points.)